Compression Measurement for Industrial Weighing Systems

CCR1(B) Series

Features
  • Canister type load cell with safe overload capacity
  • Suitable for weighing systems where overload is temporarily caused by falling measured goods
Resources
CAD Files CCR1B-500K
CAD Files CCR1-5T
CAD Files CCR1-20T
Specification Sheet No.KT52994-2
Instruction manual (PDF) No.KT60253-1
Specifications
Rated capacity
4.903 kN {500 kgf}~196.1 kN {20 tf}
Safe overload
500% R.C.
Ultimate overload
500% R.C.
Rated output
2 mV/V±0.008 mV/V
Non-linearity
0.2% R.O.
Hysteresis
0.1% R.O.
Repeatability
0.1% R.O.
Excitation, recommended
12 V or less
Excitation, maximum
20 V
Zero balance
±0.02 mV/V
Input resistance
350 Ω±3.5 Ω
Output resistance
350 Ω±5 Ω
Insulation resistance
2,000 MΩ or more (DC50 V) (between bridge and main body)
Temp. range, compensated
-10℃ ~ 70℃
Temp. range, safe
-20℃ ~ 100℃
Temp. effect on zero
0.05% R.O./10℃
Temp. effect on output
0.1% LOAD/10℃
Cable
φ10, 4 -cores shielded 3 m cable directly attached, Y-crimp type terminal lugs are attached at cable end.
Class of protection
IP64 or equivalent
Material of element
Alloy steel
Paint
Painted by epoxy resin (Munsell 6GY3.5/2 half-polished resemblance color)
Durability
1,000,000 times with rated load applied.
List of Part Numbers
Parts No.
Rated capacity
Natural frequency
Rated displacement
Weight
(Approx.)
CCR1B-500K
4.903 kN {500 kgf}
4 000 Hz
0.04 mm
4 kg
CCR1B-1T
9.807 kN {1 tf}
4 600 Hz
0.05 mm
4 kg
CCR1B-2T
19.61 kN {2 tf}
4 700 Hz
0.10 mm
4 kg
CCR1-5T
49.03 kN {5 tf}
3 500 Hz
0.09 mm
8 kg
CCR1-10T
98.07 kN {10 tf}
4 000 Hz
0.14 mm
8 kg
CCR1-20T
196.1 kN {20 tf}
3 500 Hz
0.17 mm
14 kg
Options