Have a question about this product?
Compression Measurement for Industrial Weighing Systems
CMP1 Series
Features
- Precise low-profile load cell for compression service
- All stainless steel construction
CAD Files | CMP1-250K |
CAD Files | CMP1-10T |
CAD Files | CMP1-20T |
Specification Sheet | No.KT51168-2-D |
Specification Sheet | No.KT60244-1-H |
Rated capacity |
2.452 kN {250 kgf}~196.1 kN {20 tf} |
Safe overload |
150% R.C. |
Ultimate overload |
200% R.C. |
Rated output |
2 mV/V±0.005 mV/V (CMP1-250K: 1 mV/V±0.005 mV/V) |
Non-linearity |
0.05% R.O. |
Hysteresis |
0.05% R.O. |
Repeatability |
0.05% R.O. |
Excitation, recommended |
12 V or less |
Excitation, maximum |
18 V |
Zero balance |
±0.02 mV/V |
Input resistance |
350 Ω±3.5 Ω |
Output resistance |
350 Ω±5 Ω |
Insulation resistance |
2,000 MΩ or more (DC50 V) (between bridge and main body) |
Temp. range, compensated |
-10℃ ~ 70℃ |
Temp. range, safe |
-20℃ ~ 80℃ |
Temp. effect on zero |
0.05% R.O./10℃ (CMP1-250K: 0.10% R.O./10℃) |
Temp. effect on output |
0.10% LOAD/10℃ |
Cable |
φ7, 4-cores shielded 10m cable directly attached, Y-crimp type terminal lugs are attached at cable end. |
Class of protection |
IP68 or equivalent |
Material of element |
Stainless steel |
Durability |
1,000,000 times with rated load applied. |
Parts No. |
Rated capacity |
Natural frequency |
Rated displacement |
Weight (Approx.) |
---|---|---|---|---|
CMP1-250K |
2.452 kN {250 kgf} |
1,900 Hz |
0.03 mm |
1.8 kg |
CMP1-500K |
4.903 kN {500 kgf} |
2,600 Hz |
0.06 mm |
1.8 kg |
CMP1-1T |
9.807 kN {1 tf} |
4,000 Hz |
0.06 mm |
1.8 kg |
CMP1-2T |
19.61 kN {2 tf} |
9,000 Hz |
0.06 mm |
1.8 kg |
CMP1-5T |
49.03 kN {5 tf} |
12,000 Hz |
0.07 mm |
1.8 kg |
CMP1-10T |
98.07 kN {10 tf} |
12,000 Hz |
0.11 mm |
2.0 kg |
CMP1-20T |
196.1 kN {20 tf} |
12,000 Hz |
0.14 mm |
3.7 kg |
Expansion plate, Mounting plate, Mounting attachment with slide-stop mechanism (Flexible stop method: FCA-CMP1-S, Steel ball method: SCA-CMP(-S)) |